18.5kW Hidrostal Submersible Pump Rebuild

Customer18.5kW Hidrostal Submersible Pump18.5kW Hidrostal Submersible Pump
Meat Processing Company

Customer Job Reference
Return 3N pump

JJ Loughran Job Reference
Job No: 2830C

Customer Contact
Engineering manager

Background

The Original Brief: Following correspondence from onsite contact, 18.5 kW Hidrostal Submersible Pump was collected by JJ Loughran on site at Meat processing works as instructed, due to failure. Pump was brought back to Workshop for evaluation.

The Solution

18.5kW Hidrostal Submersible Pump Rewind18.5kW Hidrostal Submersible Pump RewindFollowing tests, pump was found to have failed due to winding failure. Pump was dismantled, dropping stator housing out of outer casing; Internal rotor was removed and stator was hydraulically pressed out of stator housing. Pump stator was rewound; coils where manufactured and fitted. Stator was stoved and varnished. Pump was rebuilt, tested and delivered back to site.