Customer
Damaged 37kW Pump
Dairy Processing Company
Customer Job Reference
Lower submersible pump No.1
JJ Loughran Job Reference
Job No: 2803C:
Customer Contact
Engineering manager
Background
The Original Brief: Following correspondence from onsite contact, 37 kW, Flygt Submersible Pump was collected by JJ Loughran on site as instructed, due to seals failure. Pump was brought back to Workshop for evaluation.
The Solution
Repaired 37kW Pump Motor
Pump was dismantled; removing stator housing from outer casing and internal rotor was removed from stator. Stator was stoved and varnished, as breakdown of seals had allowed water ingress. New seals where fitted to pump and pump was rebuilt and tested. Repaired pump was loaded for transit and delivered back to site.
37kW Pump being loaded for return to Customer